On this page
On 24 November 2026 Broadcom published VMSA-2026-0011, an advisory covering 23 flaws across vCenter, ESX, Workstation, Fusion, VMware Tools and Avi Load Balancer. The one that matters most is CVE-2026-123903: an authentication bypass in the VMware Directory Service inside vCenter, rated 9.8. Anyone who can reach that service on the network can get in without a password.
This is the second critical vCenter authentication bypass in five days. The first, CVE-2026-123890, was fixed on 19 November and is already on CISA's list of exploited vulnerabilities. If you patched last week, you may still need to patch again. This brief covers what is known, who needs to act, how to check your exposure, what to look for in your logs, and what to do this week.
What happened
Broadcom's advisory VMSA-2026-0011, issued on 24 November 2026, rates the advisory as a whole Critical. It contains four critical issues:
- CVE-2026-123903 (vCenter, 9.8): authentication bypass in the VMware Directory Service.
- CVE-2026-123910 and CVE-2026-123911 (ESX, 9.8): a heap out-of-bounds write and a use-after-free in the ESX I/O filter service, which can lead to code execution on the host for an attacker with network access to ESX.
- CVE-2026-123912 (ESX, Workstation, Fusion, 9.3): an out-of-bounds write in the virtual XHCI USB controller that lets an administrator of a virtual machine run code in the VMX process on the host.
The other 19 are rated Important, Moderate or Low.
Broadcom's supplemental FAQ says the critical issues "qualify under ITIL methodologies as an emergency change". In plain terms: do not wait for the next maintenance window.
Rapid7 reports that CVE-2026-123903 is reached over LDAP, whereas last week's CVE-2026-123890 was reachable over RPC. Broadcom's FAQ confirms the two are separate flaws. Rapid7 also says a public proof of concept exists and that it validated the bypass with it. Neither Broadcom nor Rapid7 reported exploitation of CVE-2026-123903 in the wild at the time of writing.
The context is what makes this urgent. CISA added CVE-2026-123890 to its Known Exploited Vulnerabilities (KEV) catalogue on 20 November 2026. Rapid7, citing Google's Mandiant, reports that a China-linked group exploited it as a zero-day from as early as September. Attackers who have just been working on vmdir now have a second bug in the same component with public exploit code.
Who is affected
According to the Broadcom advisory, CVE-2026-123903 affects:
| Product | Affected | Fixed in |
|---|---|---|
| vCenter (VCF / vSphere Foundation 9.1) | 9.1.x | 9.1.2 |
| vCenter (VCF / vSphere Foundation 9.0) | 9.0.x | 9.0.2.0300 |
| vCenter 8.0 | 8.0 | 8.0 U3m |
| VMware Cloud Foundation 5.x | 5.x | 5.2.5 |
| vCenter 7.0 | 7.0 | Contact Broadcom support (extended support only) |
| Telco Cloud Platform / Infrastructure | Listed versions | KB463501 |
Three details change who needs to act:
- If you are on 8.0 U3m already, vCenter is covered. Broadcom's FAQ and Rapid7 both say that 8.0 U3m, the build that fixed CVE-2026-123890, also fixes CVE-2026-123903.
- If you are on 9.x and patched last week, you are not covered. The fixes for CVE-2026-123890 on 9.x were 9.1.1.0200 and 9.0.2.0200. CVE-2026-123903 needs 9.1.2 or 9.0.2.0300. A green "patched for VMSA-2026-0009" status on a 9.x estate does not mean you are safe from this one.
- Older versions should be presumed affected. vSphere 7.0 left general support on 2 October 2025 and its fix is only available through extended support. Broadcom's FAQ says to presume 6.5, 6.7 and 7.0 are affected. If you still run these, network isolation is your main defence until you upgrade.
The directory service issues apply whether or not Enhanced Linked Mode is in use. If you run an appliance built on vSphere, ask its vendor for guidance.
Updating vCenter does not fix the ESX flaws. Hosts need their own update, which needs a restart after moving workloads off with vMotion.
How to check your exposure
Work through these in order.
1. Find every vCenter and its build
Do not rely on the asset register. List every vCenter Server Appliance, including lab, disaster recovery and "temporary" ones. Broadcom's FAQ gives a PowerCLI check after connecting:
Connect-VIServer -Server vcenter.example.com
$global:DefaultVIServer.Version
$global:DefaultVIServer.Build
# And for the hosts it manages
Get-VMHost | Select-Object Name, Version, Build
Compare each result against the table above. Record 9.x systems separately, because those are the ones most likely to have been patched for last week's flaw and assumed safe.
2. Find out who can reach vmdir
The flaw needs network access to the directory service. Broadcom's knowledge base documents vmdir on TCP 389 (LDAP) and 636 (LDAPS), and lists these among the ports open between vCenter instances in Enhanced Linked Mode. Check your firewall rules for which networks can reach those ports on each vCenter. Use Broadcom's Ports and Protocols tool to confirm the full list for your version.
The answer should be a short list: other vCenter instances in the same SSO domain, and a small management network. If user VLANs, VPN pools or the whole server network can reach vCenter, a single compromised laptop or web server is enough to reach vmdir.
3. Confirm vCenter is not on the internet
vCenter's management interfaces should never be reachable from the internet. Test from outside your network, not from a firewall rule review. When we look at an organisation's external attack surface, forgotten management interfaces on cloud-hosted or disaster recovery environments are a recurring theme. If any vCenter answers from outside, treat that system as possibly compromised, not only as unpatched.
Detection
Broadcom has published no indicators of compromise for this advisory. The checks below look for the effects of an authentication bypass: access from unexpected places and changes to who holds power. They are starting points; we have not tested them against exploitation of this CVE.
Network: who talks to vmdir
Connections to vCenter on TCP 389 or 636 should come only from the vCenter instances in the same SSO domain and from systems you have deliberately configured. Anything else is worth a look. If you collect firewall or NetFlow logs in a SIEM, a query of this shape is a reasonable start:
// Connections to vCenter's directory service from outside an allow-list.
// Adjust table and field names to your firewall or flow log source.
let vcenters = dynamic(["10.0.0.10", "10.0.0.11"]);
let allowed_sources = dynamic(["10.0.0.10", "10.0.0.11", "10.0.0.50"]);
FirewallLogs
| where TimeGenerated > ago(30d)
| where DestinationIP in (vcenters) and DestinationPort in (389, 636)
| where SourceIP !in (allowed_sources)
| summarize connections = count(), first_seen = min(TimeGenerated), last_seen = max(TimeGenerated)
by SourceIP, DestinationIP, DestinationPort
| order by first_seen asc
Look back at least to early September 2026, which is when exploitation of the sibling flaw reportedly began. Rapid7 also states that it has published network detection rules for the public proof of concept to its own customers; if you use their tooling, enable them.
Identity: changes inside the SSO domain
An attacker who bypasses authentication will usually want lasting access. In vCenter, check for:
- New local SSO users in
vsphere.local(or your custom SSO domain), especially ones added to the Administrators group. - New members of privileged SSO groups, and new global permissions or roles granted at the top of the inventory.
- Changes to identity sources, such as a new LDAP or Active Directory source you did not add.
- Sign-ins by administrator accounts from hosts that do not normally manage vCenter.
On the appliance, the directory service and SSO logs live under /var/log/vmware/vmdird/ and /var/log/vmware/sso/ on recent versions. Forward them to your SIEM if you do not already. Logs that stay on a system an attacker controls can be edited.
Activity: what an attacker does next
Access to vCenter is usually a step towards something else. Watch for virtual machines being exported, cloned or having snapshots taken unexpectedly; SSH being enabled on ESX hosts; new virtual machines that do not appear in your change records; and datastore file browsing by unusual accounts. These matter most for virtual machines running domain controllers, backup servers and certificate services.
Mitigation
In order of priority:
- Patch vCenter as an emergency change. Move to 9.1.2, 9.0.2.0300, 8.0 U3m or VCF 5.2.5. Broadcom says these updates are not eligible for vCenter Quick Patch, so use the normal update process. Management interfaces go offline briefly during the update; running workloads keep running.
- Restrict network access to vCenter now, whatever your patch date. Limit TCP 389, 636 and the management ports to the other vCenter instances and a dedicated management network or jump host. This is the only meaningful interim control, because Broadcom lists no workaround.
- Patch ESX next. CVE-2026-123910 and CVE-2026-123911 need ESX 9.1.2, 9.0.2.0200, ESXi 8.0 U3m or VCF 5.2.5, applied with a host restart.
- Remove unneeded USB controllers from virtual machines. For CVE-2026-123912, Broadcom notes that a virtual machine without an XHCI controller does not present the vulnerable device. Test first, because it can affect console input.
- Review the SSO domain after patching. Patching closes the door. It does not remove an administrator account added before you patched. Run the identity checks above on every vCenter.
If you find an unknown administrator account, unexplained access to vmdir or virtual machines exported without a change record, stop treating this as a patching task. Preserve the appliance logs before you rebuild anything and follow your incident response plan. Our post on the first 24 hours of a ransomware incident explains why: attackers who reach the hypervisor layer often go for backups next.
What we know and what is unconfirmed
As of 26 November 2026, 05:00 UTC.
Stated in Broadcom's advisory and FAQ:
- VMSA-2026-0011 was issued on 24 November 2026 and covers 23 issues.
- CVE-2026-123903 is an authentication bypass in the VMware Directory Service in vCenter, rated 9.8, with no workaround.
- Fixed versions are 9.1.2, 9.0.2.0300, 8.0 U3m and VCF 5.2.5; vCenter 7.0 customers must contact Broadcom support.
- The vCenter updates are not eligible for Quick Patch.
Reported by Rapid7, not stated in the Broadcom text we reviewed:
- The flaw is reached over LDAP, unlike CVE-2026-123890, which is reachable over RPC.
- A public proof of concept exists, and Rapid7 has validated it.
Confirmed for the sibling flaw, CVE-2026-123890:
- It is in CISA's KEV catalogue, added on 20 November 2026. We checked the catalogue in this run: CVE-2026-123903 was not listed as of its 25 November 2026 update.
Unconfirmed or unknown:
- Whether CVE-2026-123903 is being exploited in the wild. No vendor or government source reports it yet.
- Whether the group behind CVE-2026-123890 exploitation also used this flaw.
- How many vCenter systems are reachable from the internet. We have not seen a reliable public count and do not quote one.
- We could not load the NVD entry for CVE-2026-123903 when preparing this brief.
We will update this brief if Broadcom revises its advisory, CISA adds CVE-2026-123903 to KEV, or credible reports of exploitation appear.
Sources
- Broadcom, VMSA-2026-0011 security advisory, 24 November 2026.
- Broadcom, VMSA-2026-0011 supplemental FAQ.
- Rapid7, CVE-2026-123903: Critical VMware Directory Service authentication bypass affects vCenter, 25 November 2026.
- Rapid7, CVE-2026-123890: Critical authentication bypass in VMware vCenter.
- CISA, Known Exploited Vulnerabilities catalogue.
- Broadcom knowledge base, Anonymous access on VMDir LDAP via port 389.